Medema Mini Crosses M2 4W Cabin User Manual Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
User guide P9-0152-B 52 of 60 Version 3.0.0/2013
Medema Production A/S
If there is an electronic fault, a number of lamps in the battery
indicator will light up. The following table shows what they
mean.
Lamps Causes Remedy
1 lamp The batteries need charging or
the connection to a battery is
poor.
Check all connections between
the controller and batteries. If
these are ne, try charging the
batteries
2 lamps Poor connection to the motor. Check the connection between
the motor and controller. Contact
supplier.
3 lamps Short-circuit between the motor
and a battery connection.
Contact supplier - say how many
lamps are lit.
4 lamps Not in use
5 lamps Not in use
6 lamps The S180/200 is prevented
from driving. Inhibit 2 is active.
This may be due to the battery
charger being connected, the
plug to the thermal switches
being disconnected, a fault
in the thermal switch or the
scooter is overheating.
The Mini Crosser will turn itself
off automatically after it has
been stationary for 10 minutes.
The battery indicator ashes
with 6 lamps at a rate of about
3 seconds.
Stop the unit and wait 3-5 minutes
before restarting. Turn the key to
0 and then to 1 to reset the fault.
Contact supplier.
To start M2 again, the key must
be turned to position 0 and back
to I.
7 lamps Accelerator fault. Contact supplier.
8 lamps Controller fault. Contact supplier.
9 lamps Poor connection to motor
brake.
Magnetic brake is disengaged.
Check the connections from brake
to controller, or push the brake
lever up.
Check that the vehicle is not
disengaged.
10 lamps The controller has been
supplied with a high voltage in
excess of 38 V. Usually seen in
the case of a poor connection.
Check all connections from the
batteries to the controller.
Running
lights
Charger is connected. Remove
charger.
Remove charger.
Running
lights from
the center
and out.
The accelerator has been
aktivated during start up.
Turn the key back to 0 and to 1 to
reset the fault.